Commissioning and Diagnostics of Power Transformers

21. - 23. Mai 2024
Großbritannien (Stafford)
Englisch
Cptr06en
DIRANA, TESTRANO 600, Primary Test Manager (PTM), FRANEO 800, CPC Produktfamilie

Übersicht

After an introduction of selective measurements to perform on power transformers, you will develop your skills through theoretical and practical sessions performing conventional and diagnostic tests with CPC 100 or TESTRANO along with the CP TD1. Furthermore, you will learn how to perform reliable Sweep Frequency Response Analysis (SFRA) measurements to detect winding deformation with FRANEO 800 and to use DIRANA to perform dielectric response measurements and determine the moisture content in oil-paper insulated power transformers.

Ziele

  • Overview of the structure of the power transformer, core, insulation, windings, bushings and the tap-changer
  • Analysis of the condition of power transformers to fully exploit the lifetime of your asset
  • Carry out time-optimized tests and diagnostics in our workshop
  • Preparing and performing SFRA measurements on power transformers
  • Using DIRANA to measure the dielectric response on power transformers and determine the moisture content
  • Applying the Primary Test Manager (PTM) software as support tool for the entire measurement process
  •  

Inhalt

  • Introduction to power transformer commissioning, maintenance, condition assessment and diagnostics 
  • Theoretical background and performance of ratio, excitation current, vector group, winding resistance, short circuit impedance measurements and demagnetization of the transformer
  • Theoretical background and performance of capacitance & power/dissipation factor (tan delta) tests on power transformers and bushings 
  • Basics and theory to understand the SFRA measurement method and connection techniques
  • Influences on the reproducibility of an SFRA measurement trace
  • Measurement of the dielectric response of power transformers
  • Understand the causes of the ageing of cellulose and insulation oil
  • Analysis of dielectric response curves
  • Sources of moisture in transformers
  • Interpretation of test results
  • A new approach to facilitated power transformer testing with a software tool (PTM) for intuitive power transformer testing and reporting
  •  

Zeiten

Day 1: 08:45 - 17:30

Day 2: 09:00 - 17:30

Day 3: 09:00 - 16:00

Information

You will receive a personal email with all course information such as agenda, route directions and hotel recommendations shortly before the training course.

Teilnehmerkreis

Technical staff from utilities or companies working mainly in commissioning or maintenance testing of power transformers.

Vorwissen

Basic knowledge of Power Transformers

Lösungen

CPC 100 
CP TD1
CP SB1
TESTRANO 600
FRANEO 800
DIRANA
Primary Test Manager (PTM)

GBP 2.040
pro Person, exkl. USt.
seats available
Zur Anmeldung

„Theorie und Praxis kamen für die einzelnen Themen nacheinander, so dass man das Gelernte direkt anwenden konnte.“

Teilnehmerfeedback

Profitieren Sie von einer effizienten Mischung aus live Vorführung des Equipments, verständlich aufbereiteten theoretischen Inhalten und praktischen Messungen.

Effiziente Trainingsmethoden

Unser erfahrener Trainer geht während des Trainings auf Ihre Fragen ein. Alle Teilnehmer erhalten die Möglichkeit ihre Fragen innerhalb der Gruppe oder mit dem Trainer zu diskutieren.

Vertiefende Diskussionen

Sie erhalten  umfassende Trainingsunterlagen, um später darin nachschlagen zu können. 

Professionelle Unterlagen
seats available
Zur Anmeldung
5 Alternative Kurstermine
27. - 29. Februar 2024
Großbritannien (Stafford)
Englisch
09. - 11. April 2024
Großbritannien (Stafford)
Englisch
02. - 04. Juli 2024
Großbritannien (Stafford)
Englisch
03. - 05. September 2024
Großbritannien (Stafford)
Englisch
08. - 10. Oktober 2024
Großbritannien (Stafford)
Englisch
Sie verwenden eine nicht unterstützte Browser-Version.
Bitte aktualisieren Sie Ihren Browser oder verwenden Sie einen anderen Browser damit diese Seite korrekt dargestellt wird.
×