29. - 31. Oktober 2024
Vereinigte Staaten von Amerika (Houston)
Englisch
Cpuc04en
DANEO 400, IEDScout, StationScout, StationGuard, CMC Produktfamilie
2in1 – IEC 61850 Fundamentals, LAN Design and Cybersecurity in Digital Substations

IEC 61850 LAN Design, Testing & Cybersecurity

29. - 31. Oktober 2024
Vereinigte Staaten von Amerika (Houston)
Englisch
Cpuc04en
DANEO 400, IEDScout, StationScout, StationGuard, CMC Produktfamilie
2in1 – IEC 61850 Fundamentals, LAN Design and Cybersecurity in Digital Substations

Übersicht

Ethernet is considered a fast, reliable, and scalable local area (LAN) technology that is becoming the predominant LAN technology within electrical substations. Through a combination of lectures and instructor demonstration lab exercises, students will learn how to correctly design and test Ethernet LANs for digital substation applications. The course will then progress to provide a strong foundation in the fundamentals of substation OT LAN cybersecurity.

Ziele

  • Understand the requirements of an IEC61850 OT Ethernet LAN
  • Understand the fundamentals of Ethernet LAN operation
  • Understand how to design, configure, and commission an Ethernet LAN for the digital substation
  • Understand the fundamentals of OT LAN cybersecurity
  •  

Inhalt

  • Introduction to IEC 61850 
  • OMICRON IEC 61850 Testing Tools
  • Ethernet Layer 1 
  • Ethernet Layer 2 
  • Operation of RSTP 
  • Configuration of primary and alternate data paths
  • Substation LAN Redundancy
  • Virtual LANs
  • Precision Time Protocol Operation
  • Ethernet Layer 3: The network layer
  • IPv4 addressing
  • Introduction to IP Static routing
    • NAT/PAT
  • Introduction to firewalling (layers 1 to 4)
  • IPsec
  • Cybersecurity attacks we can learn from
  • Substation Cybersecurity
    • IT versus OT-security versus substations
    • FERC, NERC & CIP
    • Defense-in-depth principle applied to the electrical substation.
    • Electrical Energy OT Substation Architecture (Purdue Model)
    • NIST Security Framework 
  • Typical substation attack vectors
  • Stateful firewalling
  • Introduction to traffic filtering beyond layer 4
    • Deep packet inspection
    • Intrusion detection
      • Signature-based intrusion detection
      • Learning-based intrusion detection
      • Functional security monitoring intrusion detection System (StationGuard)
      • Demonstration
  •  

Dauer

3 days

Zeiten

8am - 5pm, each day

You will receive a tentative confirmation within a couple days of registering.  

Do NOT purchase any flights until you receive the FINAL confirmation confirming that we will still be hosting the in-person class.

 

Information

This class is eligible for PDH and NETA Credits.
 

Teilnehmerkreis

Electrical Engineering staff, IT and Security officers from utilities, transmission and distribution networks, railway grids, service companies, and manufacturers involved in protection design.

Vorwissen

Basic knowledge of electrical engineering

Lösungen

DANEO 400, IEDScout, StationScout, StationGuard, Quick CMC, CMC GOOSE module, CMC IEC61850 Client/Server module

Agenda

Day 1

    Introduction to IEC61850 Services 

  • GOOSE
  • Sampled Values
  • Overview of OMICRON Testing Solutions
  •  

    Ethernet Fundamentals

  • Modern Ethernet Media
  • Basic Hub Operation
  • Basic Switch Operation
  •  

    Overview Switch General Management Features

  • Admin and User accounts
  • Time
  • Switch system internal log
  • Syslog
  • Switch IEC61850 buffered reports
     
  • Instructor demonstration exercise Lab 1: 
    o    Switch Web-based Network Management Interface 
    o    Configuration and observation of syslog. 
    o    Examining switch IEC 61850 Data model and buffered report operation using IEDScout.
  •  

    The Ethernet Frame

  • Media Access Control (MAC) Address
  • Switch Learning
  • Port Mirroring
     
  • Instructor Demonstration Lab 2: LAN latency measurement of GOOSE using the DANEO 400 
  •  

    Network Redundancy

  • Overview of RSTP Operation
  • Instructor Demonstration Lab 3: RSTP configuration and failover time measurement using the DANEO 400
  • Parallel Redundancy Protocol (PRP)
  • Highly Available Seamless Redundancy Protocol (HSR)
     
  • Instructor Demonstration Lab 4:  
    o   Testing DANEO 400 GOOSE Supervision Operation OVER a PRP Network
  •  

Day 2


    IEEE 802.1Q Header

  • Priority
  • VLANs
  •  

    MMS, GOOSE, and SV filtering using VLAN and priority

  • Student Lab 5: VLAN design exercise. 
  • Instructor Demonstration Lab 6: VLAN configuration and testing exercise
  • Configuring trunk and edge ports for GOOSE and MMS. 
  • Verification using the DANEO 400 and IED Scout for both the normal and failover traffic path.
  • Troubleshooting using DANEO 400 and StationScout
  •  

    Introduction to precision time protocol (PTP)

  • Overview of PTP operation and settings.
  • Instructor Demonstration Lab 7: Examination of PTP operation and redundancy followed by a discussion of considerations for substation LAN design. 
  • Overview of sampled values relay test procedures.
  • Instructor Demonstration Lab 8: Configuration of a CMC test set for sampled values testing:
        CMC Hardware configuration
        CMC Quick CMC 
        Optional: CMC GOOSE module and CMC IEC 61850 Client/Server module
  •  

Save money by registering for both our IEC 61850 classes happening October 29-31 and November 12-14, 2024.

Weiterlesen
USD 1.650
pro Person, exkl. USt.
Zur Anmeldung

„Es ist wirklich erstaunlich und ziemlich einfach für mich das Thema durch die Beispiele des Trainers zu verstehen.“

Teilnehmerfeedback

Mit unseren Kursen gewinnen Sie Fachwissen über Betriebsmittel und Anwendungen in elektrischen Energiesystemen. 

Anwendungswissen

Profitieren Sie von einer effizienten Mischung aus live Vorführung des Equipments, verständlich aufbereiteten theoretischen Inhalten und praktischen Messungen.

Effiziente Trainingsmethoden

Sie erhalten  umfassende Trainingsunterlagen, um später darin nachschlagen zu können. 

Professionelle Unterlagen
Sie verwenden eine nicht unterstützte Browser-Version.
Bitte aktualisieren Sie Ihren Browser oder verwenden Sie einen anderen Browser damit diese Seite korrekt dargestellt wird.
×