Time-optimized power transformer diagnostics with TESTRANO 600

20. - 21. Mai 2021
Australien (Melbourne)
Englisch
Cptr02en
TESTRANO 600

Übersicht

After an introduction into the maintenance of transformers, you will expand your knowledge in theory and practice with the TESTRANO 600 means of turns ratio, winding resistance and capacitance or dissipation/power factor measurements. Practical measurements will enable you to gain immediate testing experience.

Ziele

  • Overview of the structure of the transformer insulation, the bushings and the tap-changer
  • Analysis of the condition of power transformers to fully exploit the lifetime of your asset
  • Carry out time-optimized tests and diagnostics in the substation, powerstation or workshop
  • Fast, simple and safe condition assessment of your power transformer
  •  

Inhalt

  • Negative influences on the expected lifetime of a transformer
  • Overview of frequent defects in transformer components and their fault patterns
  • Construction of the transformer insulation, the bushings and the tap-changer
  • Common conventional measurement methods such as turns ratio, winding resistance, short-circuit impedance and demagnetization of the transformer
  • Theoretical background to capacity and dissipation/power factor measurements of winding and bushing insulation
  • Automatic execution of three-phase measurements using the Primary Test Manager (PTM) software
  • Evaluation of the measurement results by means of practical examples
  • Assessment of diagnostic measurements and recognize possible defects and influences
  • Analyzing case studies of most common defects on various power transformers
  •  

Dauer

2 days

Information

You will receive a personal email with all course information such as agenda and route directions shortly before the training course.

Teilnehmerkreis

Technical staff involved in transformer testing in utilities, transmission, distribution and generation networks, railway grids, service companies and manufacturers.

Vorwissen

Knowledge of electrical engineering

Lösungen

TESTRANO 600
Primary Test Manager (PTM)

AUD 880,00
pro Person, inkl. GST
Seats available

„Was mich wirklich beeindruckt, ist die Flexibilität des Trainers alle Fragen mit der richtigen Methode für jede einzelne Person zu beantworten.“

Teilnehmerfeedback

Mit unseren Kursen gewinnen Sie Fachwissen über Betriebsmittel und Anwendungen in elektrischen Energiesystemen. 

Anwendungswissen

Unser erfahrener Trainer geht während des Trainings auf Ihre Fragen ein. Alle Teilnehmer erhalten die Möglichkeit ihre Fragen innerhalb der Gruppe oder mit dem Trainer zu diskutieren.

Vertiefende Diskussionen

Sie erhalten  umfassende Trainingsunterlagen, um später darin nachschlagen zu können. 

Professionelle Unterlagen