November 13 - 16, 2023
Qatar (Doha)
English
Cprs19en
Test Universe, ADMO Time Grading, CMC Family

Automated Power System Protection Testing

November 13 - 16, 2023
Qatar (Doha)
English
Cprs19en
Test Universe, ADMO Time Grading, CMC Family

Summary

You will learn how to efficiently test overcurrent, distance and transformer differential relays with the OMICRON Test Universe. Become familiar with the test procedures in theoretical and hands-on sessions and get to know the benefits of automated testing and reusable test templates.

Objectives

  • Get familiar with the CMC test set and the Test Universe software for testing overcurrent protection relays
  • Get to know important safety aspects for test preparation and execution
  • Refresh your technical knowledge of overcurrent, distance and differential protection
  • Be able to choose the appropriate software modules for testing distance and transformer differential relays
  • Become more efficient in testing by creating and expanding reusable test plans
  • Know the OMICRON support options including technical support, knowledge library and the worldwide community
  • Get to know the full range of OMICRON solutions for protection testing
  •  

Content

  • Power system protection principles and typical substation topologies
  • Overview of protection testing basics
  • Introduction to the OMICRON Control Center (OCC) and relevant test modules
  • Modelling of the relay characteristics in the Test Object for subsequent testing
  • Test setup and configuration options for the CMC test set
  • Quick current and voltage output for easy wiring tests
  • Fundamentals of non-directional overcurrent protection functions
  • Creating a reusable test plan (OCC file) for testing non-directional overcurrent relays
  • Hands-on testing of non-directional overcurrent protection
  • Fundamentals of distance, ground fault and transformer differential protection functions
  • Creating a reusable test plan for testing distance relays
  • Creating a reusable test plan for testing transformer differential relays
  • Testing ground fault protection with RelaySimTest using realistic network simulation
  • Hands-on testing of distance and transformer differential relays as well as ground fault protection function
  •  

Duration

4 days

Schedule

Everyday 9:00 - 17:00 (GMT+3:00)

Information

Last date to register is November 5th, 2023

You will receive a personal email with all course information such as agenda and venue information shortly before the training course.

Audience

Technical staff from utilities or companies working mainly in commissioning or maintenance testing

Prerequisites

Basic knowledge of power system protection

Solutions

Test Universe: QuickCMC, Ramping, Pulse Ramping, State Sequencer, Overcurrent, Advanced Distance, Advanced Differential
OMICRON Control Center
RelaySimTest, CMControl, ADMO
CMC-Family

EUR 3,160
per person, excludes tax
Register Now

„It is really amazing and pretty easy for me to understand the matter with the examples the trainer has carried out.“

Student's feedback

Through our courses, you will gain thorough knowledge of assets and applications in electrical power systems.

Application knowledge

Benefit from an efficient mix of live presentations of the device, logically arranged theory content and practical measurements.

Efficient training methods

You will receive comprehensive manuals for later reference. 

Professional training material
11 Alternative Course Dates
July 11 - 13, 2023
India (New Delhi)
English
June 27 - 29, 2023
United Kingdom (Stafford)
English
September 26 - 28, 2023
United Kingdom (Stafford)
English
October 10 - 12, 2023
United Kingdom (Stafford)
English
October 31 - November 2, 2023
United Kingdom (Stafford)
English
November 28 - 30, 2023
United Kingdom (Stafford)
English
December 6 - 8, 2023
India (New Delhi)
English
October 3 - 5, 2023
Finland (Tampere)
English
November 7 - 9, 2023
United Kingdom (Stafford)
English
October 10 - 12, 2023
Sweden (Solna)
English
April 9 - 11, 2024
Iceland (Reykjavík)
English
You are using an outdated browser version.
Please upgrade your browser or use another browser to view this page correctly.
×