Commissioning and Diagnostics of Power Transformers

9 - 11 de abril de 2024
Reino Unido (Stafford)
inglés
Cptr06en
DIRANA, TESTRANO 600, Primary Test Manager (PTM), FRANEO 800, Familia de productos CPC

Resumen

After an introduction of selective measurements to perform on power transformers, you will develop your skills through theoretical and practical sessions performing conventional and diagnostic tests with CPC 100 or TESTRANO along with the CP TD1. Furthermore, you will learn how to perform reliable Sweep Frequency Response Analysis (SFRA) measurements to detect winding deformation with FRANEO 800 and to use DIRANA to perform dielectric response measurements and determine the moisture content in oil-paper insulated power transformers.

Objetivos

  • Overview of the structure of the power transformer, core, insulation, windings, bushings and the tap-changer
  • Analysis of the condition of power transformers to fully exploit the lifetime of your asset
  • Carry out time-optimized tests and diagnostics in our workshop
  • Preparing and performing SFRA measurements on power transformers
  • Using DIRANA to measure the dielectric response on power transformers and determine the moisture content
  • Applying the Primary Test Manager (PTM) software as support tool for the entire measurement process
  •  

Contenido

  • Introduction to power transformer commissioning, maintenance, condition assessment and diagnostics 
  • Theoretical background and performance of ratio, excitation current, vector group, winding resistance, short circuit impedance measurements and demagnetization of the transformer
  • Theoretical background and performance of capacitance & power/dissipation factor (tan delta) tests on power transformers and bushings 
  • Basics and theory to understand the SFRA measurement method and connection techniques
  • Influences on the reproducibility of an SFRA measurement trace
  • Measurement of the dielectric response of power transformers
  • Understand the causes of the ageing of cellulose and insulation oil
  • Analysis of dielectric response curves
  • Sources of moisture in transformers
  • Interpretation of test results
  • A new approach to facilitated power transformer testing with a software tool (PTM) for intuitive power transformer testing and reporting
  •  

Horario

Day 1: 08:45 - 17:30

Day 2: 09:00 - 17:30

Day 3: 09:00 - 16:00

Información

You will receive a personal email with all course information such as agenda, route directions and hotel recommendations shortly before the training course.

Audiencia

Technical staff from utilities or companies working mainly in commissioning or maintenance testing of power transformers.

Conocimiento previo

Basic knowledge of Power Transformers

Soluciones

CPC 100 
CP TD1
CP SB1
TESTRANO 600
FRANEO 800
DIRANA
Primary Test Manager (PTM)

GBP 2.040
por persona, impuestos no incluidos
only 1 seat available
Regístrese

„El contenido del curso fue impartido eficazmente en un ambiente muy agradable. ¡Buen trabajo!“

Comentarios del estudiante

Se beneficiará de una eficiente mezcla de presentaciones activas, de un arreglo de contenido teórico y mediciones prácticas sobre.

Métodos de capacitación eficientes

Nuestro experimentado instructor incorporará sus preguntas en el programa. Cada participante tendrá la posibilidad de discutir cualquier cuestión que le pueda surgir con otros miembros del grupo y con el instructor.

Discusiones detalladas

Recibirá manuales completos para su posterior consulta.

Material de capacitación profesional
only 1 seat available
Regístrese
5 Fechas alternativas de formación
27 - 29 de febrero de 2024
Reino Unido (Stafford)
inglés
21 - 23 de mayo de 2024
Reino Unido (Stafford)
inglés
2 - 4 de julio de 2024
Reino Unido (Stafford)
inglés
3 - 5 de septiembre de 2024
Reino Unido (Stafford)
inglés
8 - 10 de octubre de 2024
Reino Unido (Stafford)
inglés
Está utilizando una versión de navegador desactualizada.