18 - 19 de noviembre de 2024
Australia (Melbourne)
inglés
oCptr02en
TESTRANO 600, Primary Test Manager (PTM), Familia de productos CPC

Live Online Training: Time-optimized power transformer diagnostics with TESTRANO 600

18 - 19 de noviembre de 2024
Australia (Melbourne)
inglés
oCptr02en
TESTRANO 600, Primary Test Manager (PTM), Familia de productos CPC

Resumen

After an introduction to the maintenance of transformers, you will expand your knowledge of transformer diagnostics and applications in theory and practice. You will get familiar with the TESTRANO 600 functions for turns ratio, winding resistance and capacitance or dissipation/power factor measurements. Practical measurements will enable you to gain immediate testing experience.

Objetivos

  • Get a comprehensive overview of the structure of the transformer insulation, the bushings and the tap-changer
  • Analyze of the condition of power transformers to fully exploit the lifetime of your asset
  • Carry out time-optimized tests and diagnostics in the substation, power station or workshop
  • Perform fast, simple and safe condition assessment of your power transformer
  •  

Contenido

  • Negative influences on the expected lifetime of a transformer
  • Overview of frequent defects in transformer components and their fault patterns
  • Construction of the transformer insulation, the bushings and the tap-changer
  • Common conventional measurement methods such as turns ratio, winding resistance, short-circuit impedance and demagnetization of the transformer
  • Theoretical background to capacity and dissipation/power factor measurements of winding and bushing insulation
  • Automatic execution of three-phase measurements using the Primary Test Manager (PTM) software
  • Evaluation of the measurement results by means of practical examples
  • Assessment of diagnostic measurements and recognize possible defects and influences
  • Analyzing case studies of most common defects on various power transformers
  •  

Duración

2 days

Audiencia

Technical staff involved in transformer testing in utilities, transmission, distribution and generation networks, railway grids, service companies and manufacturers.

Conocimiento previo

Knowledge of electrical engineering

Soluciones

TESTRANO 600
Primary Test Manager (PTM)

AUD 660
por persona, impuestos no incluidos
Regístrese

„Lo que más me impresiona es la flexibilidad del instructor para responder a todas las preguntas con el método que más se adecúa a cada persona.“

Comentario del estudiante

Se beneficiará de una eficiente mezcla de presentaciones activas, de un arreglo de contenido teórico y mediciones prácticas sobre.

Métodos de capacitación eficientes

Nuestro experimentado instructor incorporará sus preguntas en el programa. Cada participante tendrá la posibilidad de discutir cualquier cuestión que le pueda surgir con otros miembros del grupo y con el instructor.

Discusiones detalladas

Recibirá manuales completos para su posterior consulta.

Material de capacitación profesional
3 Fechas alternativas de formación
3 de diciembre de 2024 - 4 de diciembre de 2023
China (Hong Kong)
inglés
19 - 20 de mayo de 2025
Australia (Melbourne)
inglés
9 - 10 de junio de 2025
China (Hong Kong)
inglés
Está utilizando una versión de navegador desactualizada.
Por favor, actualice su navegador o utilice otro para ver correctamente esta página.
×