Power System Protection Testing with the OMICRON Test Universe
Resumen
Learn how to efficiently test overcurrent, distance and transformer differential relays with the OMICRON Test Universe. Get familiar with the test procedure in hands-on and theoretical sessions. Work with special test set-ups that simulate the substation in the classroom.
Objetivos
- Performing commissioning, trouble-shooting and periodic tests of protection relays
- Testing overcurrent, distance and transformer differential relays with the OMICRON Test Universe
- Creating and modifying automated test plans and customized test reports
- Using the OMICRON Test Universe from scratch
Contenido
- Quick current and voltage output for easy wiring tests
- Configuration of the test object parameters and the test hardware
- Creating test plans which adapt automatically to newly entered relay settings
- Creating a flexible test plan for overcurrent relays including testing pick-up values and trip times
- Hands-on testing of the overcurrent protection function
- Creating a flexible test plan for distance relays including testing the trip times and zone reaches as well as switch on to fault (manual close) and auto-reclosing
- Hands-on testing of distance relays
- Creating a flexible test plan for transformer differential relays including testing the stability during external faults, the tripping characteristic, the trip times and the harmonic restraints
- Hands-on testing of transformer differential relays
Duración
3 days
Horario
Day 1: 01:00 p.m. - 05:00 p.m.
Day 2: 08:00 a.m. - 04:00 p.m.
Day 3: 08:00 a.m. - 04:00 p.m.
Day 4: 08:00 a.m. - 12:00 p.m. and 01:00 p.m. - 04:00 p.m. (optional hands-on)
You will receive a tentative confirmation within a couple days of registering.
Do NOT purchase any flights until you receive the FINAL confirmation confirming that we will still be hosting the in-person class.
This class is eligible for PDH, NETA and IACET Credits.
Información
Agenda
Day 1 (half-day)
> Introduction
> Testing Philosophy
> CMC Hardware Overview
> Test Universe Start Page
> Creating a new test plan
> How to use the QuickCMC test module
Day 2
> Overcurrent protection and fault types
> How to use the Overcurrent test module
> Hands-on Exercise
> Reclosing logic and protection overview
> How to use the State Sequencer test module
> Hands-on Exercise
> Underfrequency, Undervoltage and other elements
> How to use the Ramping tool
> Hands-on Exercise
Day 3
> Distance Protection Overview
> How to use the Advanced Distance test module
> Hands-on Exercise
> Differential Protection Overview
> How to use the Advanced Differential test modules
> Hands-on Exercise
Day 4 (half-day)
> XRIO Basics
> How to make a test plan adaptable to relay settings
> How to use the Protection Testing Library
> General tips for making the most efficient test plans
> Open time for other topics (End-to-End, 61850, Meter Testing, etc.)
Audiencia
Technical staff from utilities, transmission and distribution networks, railway grids, service companies and manufacturers involved in protection testing
Conocimiento previo
Basic knowledge of power system protection, or ideally attendance of the course Cprs51en
Soluciones
Control Center
QuickCMC
Ramping
Pulse Ramping
Overcurrent
Advanced Distance
State Sequencer
Autoreclosure
Advanced Differential
CMC-Family
„Los conocimientos teóricos y prácticos se impartieron uno después del otro para que todo lo aprendido pudiera ser aplicado inmediatamente.“