13 - 14 de octubre de 2026
Estados Unidos (Houston)
inglés
Cprs21en
OMICRON Control Center, QuickCMC, Pulse Ramping, State Sequencer, Overcurrent, Test Universe, Protection Testing Library (PTL), Familia de productos CMC

Protection Testing 101 – Basics and Overcurrent with Test Universe

13 - 14 de octubre de 2026
Estados Unidos (Houston)
inglés
Cprs21en
OMICRON Control Center, QuickCMC, Pulse Ramping, State Sequencer, Overcurrent, Test Universe, Protection Testing Library (PTL), Familia de productos CMC

Resumen

Learn how to test basic relay protection and schemes with OMICRON Test Universe. This course covers voltage, frequency, and overcurrent protection in an environment for new or basic users of protection testing. Get familiar with the test procedure in hands-on and theoretical sessions. Work with test setups wired to mimic real-world conditions.

Objetivos

  • Periodic commissioning, troubleshooting, and periodic tests of protection relays
  • Testing overcurrent relays with OMICRON Test Universe
  • Creating and modifying test plans and customized test reports
  • Using OMICRON Test Universe from scratch
  • Using the OMICRON Protection Testing Library (PTL)
  •  

Contenido

  • Quick current and voltage output for easy wiring checks
  • Configuration of the Test Object parameters and the test hardware
  • Creating test plans from scratch
  • Creating a flexible test plan for voltage-based protection including testing pick-up values and trip times
  • Hands-on testing of voltage and frequency elements in relays
  • Creating test plans for overcurrent protection including testing pick-up values and trip times
  • Hands-on testing of overcurrent relays
  • Introduction to the OMICRON Protection Testing Library (PTL)
  •  

Duración

2 days

Horario

8am - 5pm each day

Audiencia

Technical staff from utilities, transmission and distribution networks, railway grids, service companies, and manufacturers involved in protection testing

Conocimiento previo

Basic knowledge of power system protection

Soluciones

Control Center,
QuickCMC,
Ramping,
Pulse Ramping,
State Sequencer,
Overcurrent,
est Universe,
PTL, CMC Family

USD 1.650
por persona, impuestos no incluidos
Regístrese

„Me resulta sorprendente y muy fácil entender la información con ejemplos elaborados por el propio instructor.“

Comentario del estudiante

A través de nuestros cursos, se familiarizará con activos y aplicaciones en sistemas de energía eléctrica.

Conocimiento de la aplicación

Se beneficiará de una eficiente mezcla de presentaciones activas, de un arreglo de contenido teórico y mediciones prácticas sobre.

Métodos de capacitación eficientes

Recibirá manuales completos para su posterior consulta.

Material de capacitación profesional
2 Fechas alternativas de formación
21 - 22 de abril de 2026
Estados Unidos (Houston)
inglés
18 - 19 de agosto de 2026
Canadá (Toronto)
inglés
Está utilizando una versión de navegador desactualizada.
Por favor, actualice su navegador o utilice otro para ver correctamente esta página.
×