Time-optimized circuit breaker diagnostics with CIBANO 500
Resumen
Get to know the CIBANO 500 and the measurement principles for circuit breakers. Learn how to perform efficient circuit breaker tests in hands-on and theoretical sessions. Simplify your tests with the PTM (Primary Test Manager).
Objetivos
- Perform commissioning, troubleshooting and periodic tests of different types of circuit breakers
- Perform all relevant circuit breakers tests with one single test setup by using optional accessories
- Straight forward assessment of circuit breakers parameters with reference results
- Fast and easy generation of test reports with CTA Suite and VOTANO Suite
Contenido
- Typical reasons for failure of circuit breakers
- Reasons for maintenance and testing of different MV and HV circuit breakers
- Overview about different types of MV and HV (live-tank, dead-tank and GIS) breakers and its components
- Comparison of conventional vs. time-efficient circuit breaker testing with CIBANO 500
- Typical tests on MV and HV circuit breakers such as static contact and dynamic resistance measurement (DRM), timing tests for main/auxiliary contacts and pre-insertion resistors, minimum pick-up tests, coil and motor current, contact travel (motion) of main contacts
- Safely perform timing tests on Gas Insulated Switchgears (GIS) with both-sides grounded using Current Sensor Measurement (CSM) method
- Automatic test execution of comprehensive circuit breaker tests with CIBANO 500 and Primary Test Manager (PTM)
- Evaluation of the measurement results by means of practical examples
- Analyzing case studies of most common defects on various circuit breakers
Duración
3 days
Horario
Tuesday 10.00 - 17.00
Wednesday 08.30 - 18:00
Thursday 08.30 - 15.00
Información
Training Location:
Bjørnstadveien 20
1712 Sarpsborg
Norway
Please book your accomodation directly with the hotel Quality Hotel™ Sarpsborg | Hotels in Sarpsborg | Strawberry
Pricing (Discount offered for delegates from the same company);
1 participant - EUR 2800
2 participants - EUR 2520 (10% discount)
3 participants - EUR 2240 (20% discount)
The price excl. VAT and includes break service, coffee and lunch all three days.
Payment terms: Invoice will be sent 30 days before the course starts (due 30 days).
Cancellation Policy:
Less than 4 weeks’ notice; 75% of the fee will be charged, if you do not send another person.
Less than 2 weeks’ notice; 100% of the fee will be charged, if you do not send another person.
Audiencia
Technical staff involved in circuit breaker testing in utilities, transmission, distribution and generation networks, railway grids, service companies and manufacturers.
Conocimiento previo
Knowledge of electrical engineering
Soluciones
CIBANO 500
CB MC2, CB TN3 and accessories
Primary Test Manager (PTM)
„Qué bueno es cuando los instructores realmente conocen del tema.“