Résumé

You will learn how to efficiently test overcurrent, distance and transformer differential relays with the OMICRON Test Universe. Become familiar with the test procedures in theoretical and hands-on sessions and get to know the benefits of automated testing and reusable test templates.

Objectifs

  • Get familiar with the CMC test set and the Test Universe software for testing overcurrent protection relays
  • Get to know important safety aspects for test preparation and execution
  • Refresh your technical knowledge of overcurrent, distance and differential protection
  • Be able to choose the appropriate software modules for testing distance and transformer differential relays
  • Become more efficient in testing by creating and expanding reusable test plans
  • Know the OMICRON support options including technical support, knowledge library and the worldwide community
  • Get to know the full range of OMICRON solutions for protection testing
  •  

Contenu

  • Power system protection principles and typical substation topologies
  • Overview of protection testing basics
  • Introduction to the OMICRON Control Center (OCC) and relevant test modules
  • Modelling of the relay characteristics in the Test Object for subsequent testing
  • Test setup and configuration options for the CMC test set
  • Quick current and voltage output for easy wiring tests
  • Fundamentals of non-directional overcurrent protection functions
  • Creating a reusable test plan (OCC file) for testing non-directional overcurrent relays
  • Hands-on testing of non-directional overcurrent protection
  • Fundamentals of distance, ground fault and transformer differential protection functions
  • Creating a reusable test plan for testing distance relays
  • Creating a reusable test plan for testing transformer differential relays
  • Testing ground fault protection with RelaySimTest using realistic network simulation
  • Hands-on testing of distance and transformer differential relays as well as ground fault protection function
  •  

Durée

3 days

Information

HILTON REYKJAVÍK NORDICA
Suðurlandsbraut 2,

Reykjavík, 108, Iceland

 

Telefon: +354 444 5000

E-post: res.reykjavíknordica@hilton.com

Public

Technical staff from utilities or companies working mainly in commissioning or maintenance testing

Prérequis

Basic knowledge of power system protection

Solutions

Test Universe: QuickCMC, Ramping, Pulse Ramping, State Sequencer, Overcurrent, Advanced Distance, Advanced Differential
OMICRON Control Center
RelaySimTest, CMControl, ADMO
CMC-Family

EUR 2 800
par personne, hors taxes
Inscription
Téléchargement

„C’est bon de savoir que les formateurs connaissent vraiment les sujets dont ils parlent.“

Commentaire de participant

Nos formations vous permettront de vous familiariser avec les équipements et les applications des réseaux électriques. 

Savoir-faire applicatif

Profitez d’un mélange efficace de présentations des équipements, de connaissances théoriques et de tests pratiques.

Méthodes de formation efficaces

Vous recevrez des supports de cours pour vous y référer ultérieurement. 

Documents professionnels
10 Autres dates de formation
11 - 13 juillet 2023
Inde (New Delhi)
Anglais
27 - 29 juin 2023
Royaume-Uni (Stafford)
Anglais
26 - 28 septembre 2023
Royaume-Uni (Stafford)
Anglais
10 - 12 octobre 2023
Royaume-Uni (Stafford)
Anglais
31 octobre - 02 novembre 2023
Royaume-Uni (Stafford)
Anglais
28 - 30 novembre 2023
Royaume-Uni (Stafford)
Anglais
06 - 08 décembre 2023
Inde (New Delhi)
Anglais
03 - 05 octobre 2023
Finlande (Tampere)
Anglais
07 - 09 novembre 2023
Royaume-Uni (Stafford)
Anglais
10 - 12 octobre 2023
Suède (Solna)
Anglais
Vous utilisez une ancienne version de votre navigateur.
Merci de mettre à jour votre navigateur ou d’utiliser un autre navigateur pour afficher cette page correctement.
×