17 - 19 juin 2025
Royaume-Uni (Stafford)
Anglais
Cprs19en
Test Universe, Famille de produit CMC

Automated Power System Protection Testing

17 - 19 juin 2025
Royaume-Uni (Stafford)
Anglais
Cprs19en
Test Universe, Famille de produit CMC

Résumé

You will learn how to efficiently test overcurrent, distance and transformer differential relays with the OMICRON Test Universe. Become familiar with the test procedures in theoretical and hands-on sessions and get to know the benefits of automated testing and reusable test templates. 

Objectifs

  • Get familiar with the CMC test set and the Test Universe software for testing overcurrent protection relays
  • Get to know important safety aspects for test preparation and execution
  • Refresh your technical knowledge of overcurrent, distance and differential protection
  • Be able to choose the appropriate software modules for testing distance and transformer differential relays
  • Become more efficient in testing by creating and expanding reusable test plans
  • Know the OMICRON support options including technical support, knowledge library and the worldwide community
  • Get to know the full range of OMICRON solutions for protection testing
  •  

Contenu

  • Power system protection principles and typical substation topologies
  • Overview of protection testing basics
  • Introduction to the OMICRON Control Center (OCC) and relevant test modules
  • Modelling of the relay characteristics in the Test Object for subsequent testing
  • Test setup and configuration options for the CMC test set
  • Quick current and voltage output for easy wiring tests
  • Fundamentals of non-directional overcurrent protection functions
  • Creating a reusable test plan (OCC file) for testing non-directional overcurrent relays
  • Hands-on testing of non-directional overcurrent protection
  • Fundamentals of distance, ground fault and transformer differential protection functions
  • Creating a reusable test plan for testing distance relays
  • Creating a reusable test plan for testing transformer differential relays
  • Testing ground fault protection with RelaySimTest using realistic network simulation
  • Hands-on testing of distance and transformer differential relays as well as ground fault protection function
  •  

Durée

3 days - FULLY BOOKED

Public

Technical staff from utilities or companies working mainly in commissioning or maintenance testing

Prérequis

Basic knowledge of power system protection

Solutions

Test Universe: QuickCMC, Ramping, Pulse Ramping, State Sequencer, Overcurrent, Advanced Distance, Advanced Differential
OMICRON Control Center
RelaySimTest, CMControl, ADMO
CMC-Family

GBP 2 100
par personne, hors taxes
Etre mis en liste d'attente
Téléchargement

„Contenu des cours excellent, superbement présenté dans un bel environnement. Félicitations !“

Commentaire de participant

Nos formations vous permettront de vous familiariser avec les équipements et les applications des réseaux électriques. 

Savoir-faire applicatif

Vos applications particulières sont discutées pendant la formation. Les participants pourront poser les questions propres à leurs 

applications. 

Discussions approfondies

Vous recevrez des supports de cours pour vous y référer ultérieurement. 

Documents professionnels
14 Autres dates de formation
17 - 19 juin 2025
Danemark (Kolding)
Anglais
09 - 11 décembre 2025
Autriche (Klaus)
Anglais
25 - 27 février 2025
Royaume-Uni (Stafford)
Anglais
11 - 13 mars 2025
Royaume-Uni (Stafford)
Anglais
25 - 27 mars 2025
Royaume-Uni (Stafford)
Anglais
29 avril - 01 mai 2025
Royaume-Uni (Stafford)
Anglais
03 - 05 juin 2025
Royaume-Uni (Stafford)
Anglais
16 - 18 septembre 2025
Royaume-Uni (Stafford)
Anglais
30 septembre - 02 octobre 2025
Royaume-Uni (Stafford)
Anglais
14 - 16 octobre 2025
Royaume-Uni (Stafford)
Anglais
11 - 13 novembre 2025
Royaume-Uni (Stafford)
Anglais
08 - 10 avril 2025
Suède (Solna)
Anglais
01 - 03 juillet 2025
Autriche (Klaus)
Anglais
21 - 23 octobre 2025
Finlande
Anglais
Vous utilisez une ancienne version de votre navigateur.
Merci de mettre à jour votre navigateur ou d’utiliser un autre navigateur pour afficher cette page correctement.
×