You will learn how to efficiently test overcurrent, distance and transformer differential relays with the OMICRON Test Universe. Become familiar with the test procedures in theoretical and hands-on sessions and get to know the benefits of automated testing and reusable test templates. 

Cel szkolenia

  • Get familiar with the CMC test set and the Test Universe software for testing overcurrent protection relays
  • Get to know important safety aspects for test preparation and execution
  • Refresh your technical knowledge of overcurrent, distance and differential protection
  • Be able to choose the appropriate software modules for testing distance and transformer differential relays
  • Become more efficient in testing by creating and expanding reusable test plans
  • Know the OMICRON support options including technical support, knowledge library and the worldwide community
  • Get to know the full range of OMICRON solutions for protection testing
  •  

Treść szkolenia

  • Power system protection principles and typical substation topologies
  • Overview of protection testing basics
  • Introduction to the OMICRON Control Center (OCC) and relevant test modules
  • Modelling of the relay characteristics in the Test Object for subsequent testing
  • Test setup and configuration options for the CMC test set
  • Quick current and voltage output for easy wiring tests
  • Fundamentals of non-directional overcurrent protection functions
  • Creating a reusable test plan (OCC file) for testing non-directional overcurrent relays
  • Hands-on testing of non-directional overcurrent protection
  • Fundamentals of distance, ground fault and transformer differential protection functions
  • Creating a reusable test plan for testing distance relays
  • Creating a reusable test plan for testing transformer differential relays
  • Testing ground fault protection with RelaySimTest using realistic network simulation
  • Hands-on testing of distance and transformer differential relays as well as ground fault protection function
  •  

Czas trwania

3 days

Informacje

HILTON REYKJAVÍK NORDICA
Suðurlandsbraut 2,

Reykjavík, 108, Iceland

 

Telefon: +354 444 5000

E-post: res.reykjavíknordica@hilton.com

 

Training Schedule:

Tuesday; 09:00 - 17:30

Wednesday; 08:30 - 17:15

Thursday; 08:30 - 15:00

 

Please see below some useful Youtube videos to watch before the training;

 https://www.youtube.com/playlist?app=desktop&list=PLzmbZeI1bhu-2qx8gUdXM1BBF8MVoBv4x 

Odbiorcy szkolenia

Technical staff from utilities or companies working mainly in commissioning or maintenance testing

Wymagania wstępne

Basic knowledge of power system protection

Rozwiązania

Test Universe: QuickCMC, Ramping, Pulse Ramping, State Sequencer, Overcurrent, Advanced Distance, Advanced Differential
OMICRON Control Center
RelaySimTest, CMControl, ADMO
CMC-Family

EUR 2 800
na osobę, bez podatków
Seats Available
Zarejestruj się
Pliki do pobrania
Seats Available
Zarejestruj się
13 Alternatywne daty szkoleń
czerwca 17 - 19, 2025
Dania (Kolding)
angielski
grudnia 9 - 11, 2025
Austria (Klaus)
angielski
marca 25 - 27, 2025
Wielka Brytania (Stafford)
angielski
kwietnia 29 - maja 1, 2025
Wielka Brytania (Stafford)
angielski
czerwca 3 - 5, 2025
Wielka Brytania (Stafford)
angielski
czerwca 17 - 19, 2025
Wielka Brytania (Stafford)
angielski
września 16 - 18, 2025
Wielka Brytania (Stafford)
angielski
września 30 - października 2, 2025
Wielka Brytania (Stafford)
angielski
października 14 - 16, 2025
Wielka Brytania (Stafford)
angielski
kwietnia 8 - 10, 2025
Szwecja (Solna)
angielski
lipca 1 - 3, 2025
Austria (Klaus)
angielski
października 21 - 23, 2025
Finlandia
angielski
października 14 - 16, 2025
Szwecja (Solna)
angielski
You are using an outdated browser version.
Please upgrade your browser or use another browser to view this page correctly.
×