28. - 30. сентября 2021
Швеция (Solna)
Английский
Cprs19en
Test Universe, ADMO

Automated Power System Protection Testing

28. - 30. сентября 2021
Швеция (Solna)
Английский
Cprs19en
Test Universe, ADMO

Сводка

You will learn how to efficiently test overcurrent, distance and transformer differential relays with the OMICRON Test Universe. Become familiar with the test procedures in theoretical and hands-on sessions and get to know the benefits of automated testing and reusable test templates.

Цели

  • Get familiar with the CMC test set and the Test Universe software for testing overcurrent protection relays
  • Get to know important safety aspects for test preparation and execution
  • Refresh your technical knowledge of overcurrent, distance and differential protection
  • Be able to choose the appropriate software modules for testing distance and transformer differential relays
  • Become more efficient in testing by creating and expanding reusable test plans
  • Know the OMICRON support options including technical support, knowledge library and the worldwide community
  • Get to know the full range of OMICRON solutions for protection testing
  •  

Контент

  • Power system protection principles and typical substation topologies
  • Overview of protection testing basics
  • Introduction to the OMICRON Control Center (OCC) and relevant test modules
  • Modelling of the relay characteristics in the Test Object for subsequent testing
  • Test setup and configuration options for the CMC test set
  • Quick current and voltage output for easy wiring tests
  • Fundamentals of non-directional overcurrent protection functions
  • Creating a reusable test plan (OCC file) for testing non-directional overcurrent relays
  • Hands-on testing of non-directional overcurrent protection
  • Fundamentals of distance, ground fault and transformer differential protection functions
  • Creating a reusable test plan for testing distance relays
  • Creating a reusable test plan for testing transformer differential relays
  • Testing ground fault protection with RelaySimTest using realistic network simulation
  • Hands-on testing of distance and transformer differential relays as well as ground fault protection function
  •  

Продолжительность

3 days

Расписание

Tuesday 10.00 - 18.00 h

Wednesday 08.30 - 16.30 h

Thursday 08.30 - 15.00 h

Информация

Training Location:

THE WINERY HOTEL

Rosenborgsgatan 20
169 74 Solna

Sweden

Mailto:info@thewineryhotel.se

Tel: +46 8 14 60 00

The Winery Hotel | Urbant vinhotell i Stockholm, Solna


You will receive a personal email with all course information such as agenda and route directions 2 weeks before the training course starts.

Please book your overnight stay directly with the hotel. The price per night 1.340,00 SEK . For support please contact us.

Price details:
The training fee contains the training itself, the refreshments, the snacks for the coffee breaks, the lunches and one dinner. Travel and accommodation costs are within the responsibility of each delegate.
The application is binding and must be completed no later than 2021-08-30 (week 35).
Invoice shall be sent immediately after your application (payment terms 30 days net).

Cancellation policy:
< 4 weeks before 75% of the fee is charged, if you do not arrange a reserve.
< 2 weeks before 100% of the fee, if you do not arrange reserve.

Слушатели

Technical staff from utilities or companies working mainly in commissioning or maintenance testing

Требования

Basic knowledge of power system protection

Решения

Test Universe: QuickCMC, Ramping, Pulse Ramping, State Sequencer, Overcurrent, Advanced Distance, Advanced Differential
OMICRON Control Center
RelaySimTest, CMControl, ADMO
CMC-Family

SEK 23 500
за одного участника, за исключением налогов
Seats available
Seats available
2 Альтернативне даты курса
09. - 11. ноября 2021
Дания (Kolding)
Английский
02. - 04. ноября 2021
Финляндия (Tampere)
Английский
Вы используете устаревшую версию браузера.
Пожалуйста, обновите ваш браузер или используйте другой браузер, чтобы данная страница отображалась корректно.
×